top of page

What's New: Level Measurement Techniques: Minimizing Guided Wave Radar Probe Buildup

Updated: Jun 7, 2022

SOLUTIONS CENTRAL | June 2022 | mrfpr.com/blog


Magnetrol Eclipse 706 GWR Probe Options


Level measurement applications in natural gas, condensate and crude processing have special requirements which are not always evident except through field experience. The potential of solids or other materials building up on a guided wave radar probe is one example. The experience of Magnetrol - AMETEK field engineers has led to the development of some simple but effective level measurement techniques to address field issues related to buildup that may not be evident in data sheets.


Natural gas, condensate and crude processing applications can experience paraffin, asphaltenes, hydrates, grit and grime. The degree to which any of these can accumulate on guided wave radar (GWR) probes varies by application. Even in applications where buildup isn’t typically prevalent, it can happen over time, during cold weather periods, or when bringing units up or down due to temperature, pressure, and process material fluctuations. Like distillation columns, chambers / cages / bridles may require cleaning from time to time. Below are some good practices that can minimize buildup and reduce maintenance time.


Features & Benefits

  • The use of enlarged coaxial GWR probes with more clearance reduces the chance for buildup to occur.

  • Consider using a chamber probe whenever possible. Magnetrol® offers a unique family of chamber probes, which combines the sensitivity and performance associated with coaxial probes with the viscosity immunity of a single rod.

  • Insulate the probe necks of overfill probes to reduce any cooling at the top of the probe inside the vessel, chamber, cage, or bridle.






  • Chambers should be insulated even in warm weather locations. The temperature differential between a warm / hot vessel (like a separator) and uninsulated chamber/cages can be significant, resulting in paraffin deposition and/or viscosity increases.

  • Insulate chamber flanges to reduce any cooling at the top of the probe.

  • Use probes with integral flushing connection to simplify flushing/dissolving paraffin or grit. Flushing connections are an option available on all Magnetrol® coaxial GWR probes.

Eclipse Model 706 Buildup Detection Feature

Although GWR technology has many advantages, as a contacting technology, the probe can be subject to build-up from process media, particularly viscous or sticky fluids. However, a GWR transmitter with advanced diagnostics can detect and monitor buildup on the probe, allowing the user to schedule cleaning and maintenance before a problem occurs. Another option is to coat the probe with PFA (or similar) to reduce friction and material buildup or assist in corrosive environments (flushing ports can also be provided for in-situ cleaning). Depending on the application, non-contact measurement technology (although not totally free of potential build-up and coating issues) may be preferable for applications with coating, corrosion, or installation concerns.

In addition to optional PFA-coated probes, Eclipse GWR transmitters have proactive diagnostics able to scan for buildup, so you know when to schedule cleaning and maintenance.


When the Eclipse Model 706 Buildup Detection Feature is enabled, the waveform is scanned every five minutes with up to five buildup locations being monitored.

CHECK BUILDUP FREQUENTLY So that an overnight issue (such as occasional condensation on the seal face of a steam probe) will be noticed.

INTERVAL RATE The interval between rate checking varies. It depends based upon the speed of the buildup increasement.

COMPARISON During a scan, when a buildup is detected, the locations are checked against all of the previously recorded locations. OUTPUT Shown as a % compared to the present threshold value, this feature can be used by the customer as a HART dynamic variable (SV, TV, or QV) for proactive maintenance.


For the buildup percentage reading, the waveform is scanned between the seal face or blocking distance (whichever is lower on the probe) and the start of the level pulse or the end of the probe (whichever is higher on the probe).



Magnetrol offers an extensive range of innovative level controls for process industries.

Click on the product brochures below or contact us for assistance.














bottom of page